Q U I CK CH I L LE R • M N -3 6 5 80 ( RE V . 0 ) • I N ST A L LA T I ON / O PE R A TI O N /S ER V I CE M A N UA L • 20.
SUB TITLE
TITLE
OPERATING INSTRUCTIONS
OPERATION
Professional Mode - Chill Mode
Touch on Home screen.
1. Choose desired Chill mode
2. Touch
to Chill by Time, or to Chill by Probe.
4. Enter desired Chill time or Probe temperature on number pad, or touch to select factory default.
5. Touch to enter or to retun to settings screen.
6. Touch to adjust Temperature, and to adjust Hold Temperature. Note: Temperatures displayed
are the last used settings.
7. Enter desired time or temperature on number pad, or touch to select factory default.
8. Touch
to enter or to retun to settings screen.
9. Touch
to start the chilling process.
The screen will indicate:
The length of time the chiller is operating in the preset mode.
The preset temperature.
The air temperature inside the chiller compartment when in Hold cycle. Will
not display until chiller goes into Hold cycle.
The temperature of all food probes.
Touch at any time to stop chill cycle.
Soft
Chill
Hard
Chill
Quick
Freeze
0ºF
38ºF
00:00:00
34ºF
0ºF
0ºF
0ºF
1
2
3
00:30:00
1 2 3
4 5 6
7 8 9
0
Komentarze do niniejszej Instrukcji