Alto-Shaam Quickchiller QC-100REMOTE Instrukcja Obsługi Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 12
Q U I CK CH I L LE R M N -3 6 5 80 ( RE V . 0 ) I N ST A L LA T I ON / O PE R A TI O N /S ER V I CE M A N UA L 11.
SUB TITLE
TITLE
QC2-100R
INSTALLATION
SITE INSTALLATION
51" (1295mm)
86" (2183mm)
77-5/8" (1970mm)
8-1/8" (205mm) Condensate Drain
Electrical Connection
14" (355mm)
Electrical
Connection
Condensate
Drain
35-1/2"
(902mm)
76" (1930mm)
15-1/2" (394mm) Hinged Left
35-1/2" (902mm) Hinged Right
17-5/8"
(447mm)
1-1/2"
(38mm)
42" (1067mm)
39" (991mm)
36" (914mm)
75-1/4" (1910mm)
10-3/4" (273mm)
PRODUCT\PAN CAPACITY
Maximum Product Capacity
Approximately 480 lb (218 kg)
maximum
volume maximum: 300 quarts (380 liters)
Maximum Chilling Capacity
Approximately 240 lb (109 kg)
maximum
voluMe MaxiMuM: 150 quaRts (190 liteRs)
full-size pans: gastRoNoRM 1/1:
Forty (40) 20" x 12" x 2-1/2" (530 x 325 x 65mm)
full-size sheet pans:
Twenty (20)* 18" x 26" x 1" on wire shelves only.
* Extra optional wire shelves required for maximun
capacity shown above.
REMOTE BTU REQUIREMENTS
freeze mode: 14,690 BTU's at 90°F ambient
-5°F (-21°C) evaporator temperature
WEIGHT
QC2-100R
net: contact factory ship: contact factory
Pan Cart net: 120 lb (54 kg) ship: 161 lb (73 kg)
Plate Cart
net: contact factory ship: contact factory
carton dimensions: (l x w x h)
57" x 44" x 93" (1448mm x 1118mm x 2362mm)